Construction : |
ABS plastic control panel |
Protection Rating : |
IP 66, NEMA 4X, ATEX zone 22, hazardous location Class II Division 2 Groups F&G |
Operating Temperature : |
-10°C to +40°C (+14°F to +104°F) |
Relative Humidity : |
20% to 80% non-condensing |
Electrical Supply : |
85 volts to 260 volts AC single phase plus earth ground; 47 Hz to 65 Hz, Construction ABS plastic control panel; 100 watts maximum |
Air Supply : |
(for AuditCheck) 5.5 bar (80 psi) |
Product Speed : |
0.5 m/min (1.7 ft/min) to 1000 m/min (3,300 ft/min) |
Outputs : |
6 Relays outputs; Relays: 250 volt AC 2 amp max. 50 volt DC 1 amp max. |
Output Allocation (selectable via menu) : |
Reject 1, Reject 2, AuditCheck, Fault, Alarm, Warning, QA lamp |
Inputs : |
6 Inputs - Active 12v DC+12 volt auxiliary supply for input sensors |
Input Allocation (selectable via menu) : |
Speed Sensor, Keylock, Product Select 1, Product Select 2, Infeed PEC, Reject Confirmation 1 (bin full), Reject Confirmation 2, External Suppression |
Communications : |
Optional AnyBus modules |
Safety and Export Approvals : |
cCSAus, CE, ATEX zone 22 |
Manufacturing Quality : |
ISO9001 certified |
Help-Text, Users Manual Languages : |
English, Spanish, French, German, Italian, Dutch, Chinese, Czech, Russian |